Anchoring threaded rod and reinforcing bar (rebar) into cracked or uncracked concrete using hammer drill or uncracked concrete using core drill
It has an extended application temperature range between 43°F and 110 °F for structural applications per ICC-ES ESR-4094 and between 38°F and 125°F for transportation infrastructure applications to AASHTO M235 & ASTM C881.
At 75°F: 16 min working time | 7 hour cure time
Adding to cart… The item has been added

Documentation

The Chas E. Phipps Tech / SDS Documents system is a search service to product information for the Concrete, Finishes, Masonry and Thermal and Moisture Protection Divisions. All documents are in pdf format and have been compiled from manufacturer websites.

TERMS AND DISCLAIMER: ANY MATERIAL ACCESSED, DOWNLOADED OR OTHERWISE OBTAINED THROUGH THIS SYSTEM IS DONE SO AT THE USER’S DISCRETION AND SOLE RISK. THE CHAS E. PHIPPS COMPANY DOES NOT GUARANTEE THE COMPLETENESS, ACCURACY, QUALITY OR CONTENT OF ANY OF THE DOCUMENTS ACCESSED, DOWNLOADED OR OTHERWISE OBTAINED THROUGH THE SYSTEM, WHICH DOCUMENTS MAY BE AMENDED, CORRECTED OR SUPERSEDED FROM TIME-TO-TIME BY THE MANUFACTURER. USERS ARE CAUTIONED TO ALWAYS CONSULT THE ORIGINAL MANUFACTURER DOCUMENTS. USERS AGREE THAT UNDER NO CIRCUMSTANCE SHALL THE CHAS E. PHIPPS COMPANY BE LIABLE IN ANY WAY FOR (1) THE CONTENT OF ANY DOCUMENTS, INCLUDING BUT NOT LIMITED TO ANY ERRORS, OMISSIONS OR CHANGES IN ANY DOCUMENTS, OR (2) ANY LOSS OR DAMAGE OF ANY KIND (INCLUDING BUT NOT LIMITED TO ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES, ATTORNEYS’ FEES AND/OR COSTS) ARISING FROM, RELATING TO OR OTHERWISE INCURRED AS A RESULT OF THE USER’S USE OR VIEWING OF SAID DOCUMENTS ACCESSED, DOWNLOADED OR OTHERWISE OBTAINED THROUGH THIS SYSTEM.

Product Description

Ultrabond HS-1CC is a code compliant, two-component, 1:1 mix ratio by volume, high performance epoxy anchoring system approved for use in cartridges and in bulk with threaded rod and reinforcing bar for cracked and uncracked concrete conditions, and internally threaded inserts in uncracked concrete in accordance with ACI 355.4 and ICC-ES AC308.

Applications:

  • Anchoring threaded rod and reinforcing bar (rebar) into cracked or uncracked concrete using hammer drill or uncracked concrete using core drill
  • Suitable for dry, water saturated, water-filled & submerged (underwater) conditions using threaded rod or rebar
  • Vertical down, horizontal, upwardly inclined and overhead installations

Features:

  • ICC-ES ESR-4094 evaluation report for cracked and uncracked concrete
  • Building code compliant in cartridge and bulk dispensing systems, IBC/IRC: 2018, 2015, 2012 & 2009
  • ICC-ES AC308 and ACI 355.4 assessed for resisting short term loading conditions up to 205 °F (96 °C)
  • UL Certified – Drinking Water System Components to NSF/ ANSI 61 & Lead Free to NSF/ANSI 372
  • Suitable for core drilled installations in dry or water saturated concrete.

Installation: 21oz cartridge uses TM22HD dispensing gun

Base Material Temperature Working Time, min Full Cure Time, min
     
43°F 45 144
50°F 35 72
75°F 16 7
90°F 12 4
110°F 3 2